electric - insurance

Grow room design, HID, fluoro, reflectors, ventilation, ballasts and wiring.
Post Reply
User avatar
rSin
Awesome Karma Dude
Awesome Karma Dude
Custom Title: world where everone gets
Location: neck deep
Has thanked: 509 times
Been thanked: 341 times
Posts: 5657
Joined: Fri Mar 26, 2010 8:12 pm

electric - insurance

Post by rSin »

after seeing a couple outlets melt down
i recomment inspecting every box in the branch circuit line your pulling regular high use out of

lots of 80's work out there builders wernt doing outlets up with through wiring best it could be


and since ive seen a couple boxes melt ive noticed connections in boxes showing signs of heat damage

inspect and wire up proper all boxes your using regular

lights
fuck
your entertainment centers can be major pulls of current too
the intolerance of the old order is emerging from the rosy mist in which it has hitherto been obscured.

User avatar
Intrinsic
Advanced Grower
Awesome Karma Dude
Awesome Karma Dude
Has thanked: 468 times
Been thanked: 579 times
Posts: 5928
Joined: Thu May 21, 2009 10:51 am

electric - insurance

Post by Intrinsic »

Yup, good idea don't wait till you smell ozone.
Timely advice.
if you have a well/pressure tank check the pressure gauge contacts for build up and pits, lot of power going through the contacts clicking on and off. Wild temperature differences
Just replace mine last week cuz u can see pits, preemptive.

User avatar
rSin
Awesome Karma Dude
Awesome Karma Dude
Custom Title: world where everone gets
Location: neck deep
Has thanked: 509 times
Been thanked: 341 times
Posts: 5657
Joined: Fri Mar 26, 2010 8:12 pm

electric - insurance

Post by rSin »

back in the days boxes were wired up just straight through the outlet
eventually learned a top job wiring the box with a pigtail to the outlet

but that wasnt the rule back when i firest learned it
the intolerance of the old order is emerging from the rosy mist in which it has hitherto been obscured.

User avatar
Jesús Malverde
Site Moderator
Karma Bhudda
Karma Bhudda
Custom Title: agridulce
Has thanked: 10 times
Been thanked: 36 times
Posts: 2320
Joined: Fri May 27, 2011 6:59 pm

electric - insurance

Post by Jesús Malverde »

Wire your own grow room or hire a pro who might narc you out? The question answers itself.
One for the rook

One for the crow

One to rot

and one to grow

User avatar
ripper5
Kosmic Karma
Kosmic Karma
Has thanked: 730 times
Been thanked: 573 times
Posts: 1275
Joined: Sun Feb 21, 2010 1:39 am

electric - insurance

Post by ripper5 »

My place could use an inspection. Regular non grow lights blow frequently.

User avatar
Intrinsic
Advanced Grower
Awesome Karma Dude
Awesome Karma Dude
Has thanked: 468 times
Been thanked: 579 times
Posts: 5928
Joined: Thu May 21, 2009 10:51 am

electric - insurance

Post by Intrinsic »

What is a 'pigtail to the outlet'?

User avatar
rSin
Awesome Karma Dude
Awesome Karma Dude
Custom Title: world where everone gets
Location: neck deep
Has thanked: 509 times
Been thanked: 341 times
Posts: 5657
Joined: Fri Mar 26, 2010 8:12 pm

electric - insurance

Post by rSin »

pigtail is the short third wire you connect into the connection in the back of the box where the lines circuit continues to down the line

this short wire then feeds the outlet itself
so the outlet isnt itself part of the branch circuit

on the cheap you can wire boxes fast and they become essential to downfeed power

in the 80's i didnt know better
was still learning and none of the contracters teaching me knew better
Last edited by rSin on Tue May 24, 2022 9:17 am, edited 2 times in total.
the intolerance of the old order is emerging from the rosy mist in which it has hitherto been obscured.

User avatar
rSin
Awesome Karma Dude
Awesome Karma Dude
Custom Title: world where everone gets
Location: neck deep
Has thanked: 509 times
Been thanked: 341 times
Posts: 5657
Joined: Fri Mar 26, 2010 8:12 pm

electric - insurance

Post by rSin »

more specifically

on a branch you got two romex's cabled into a box
you have to make them connect

in the old days you just stripped the wires and plugged them into the outlet
it works but effectively the current through the box has running through the outset to get along

what you want to do is make the through power through a good wire nut
and you add a third wire thats short to power the outlet off of that connection

pigtail
the intolerance of the old order is emerging from the rosy mist in which it has hitherto been obscured.

User avatar
rSin
Awesome Karma Dude
Awesome Karma Dude
Custom Title: world where everone gets
Location: neck deep
Has thanked: 509 times
Been thanked: 341 times
Posts: 5657
Joined: Fri Mar 26, 2010 8:12 pm

electric - insurance

Post by rSin »

it gets complicated when a box has a switched circuit but most of your boxes dont have this detail

sorry
im rambling
the intolerance of the old order is emerging from the rosy mist in which it has hitherto been obscured.

User avatar
Intrinsic
Advanced Grower
Awesome Karma Dude
Awesome Karma Dude
Has thanked: 468 times
Been thanked: 579 times
Posts: 5928
Joined: Thu May 21, 2009 10:51 am

electric - insurance

Post by Intrinsic »

Got it. Thanks!!